The EMPIRE
EUDS provides unequaled
cooking line versatility,flexibility and convenience.
One
connection for
all your utility needs
The EMPIRE Utility Distribution
System (EUDS) is designed to meet all electrical and plumbing requirements
for your kitchen appliances. A two compartment raceway houses either an
electric copper bus bar or wireway which is completely isolated from the
plumbing supply manifolds.
Efficiency for
Today - Flexibility for Tomorrow
The utility distribution system
allows greater flexibility over conventional utility connections. It is
designed to provide additional capacity according to job specifications.
Spare connection points are provided for future cooking equipment
expansion; therefore adding new equipment requires minimal effort.
Rearranging the cooking line-up can be accomplished in a matter of
minutes, especially when equipment is on casters.
Electrical
Riser: Main power connection is made to the main
circuit breaker which has a shunt trip and is mounted in the electrical
riser.
Bus bar
systems: Electrical power is fed through the main
circuit breaker to the bus bar system in the raceway. Each appliance is
fed from the bus bar through individually sized circuit breakers located
along the raceway.
Wireway
systems: Electrical power is fed through a main
circuit breaker to a distribution panel which contains individual branch
breakers. Each appliance is fed from the individual breakers which are
wired to each receptacle located along the raceway.
Plumbing
Riser: The plumbing riser houses manual
(quarter-turn) shut-off valves for each incoming main supply line located
in the UDS. The plumbing manifolds are provided with stub-outs along the
raceway for the individual plumbing connections. Each stub-out is equipped
with a manual (quarter-turn) shut-off valve.
FEATURES:
UL Listed (File ##81368), NSF
Listed
2 Models
Available:
- EUDI: Island configuration
with equipment connections on both sides
- EUDW:Wall mounted with
equipment connections on one side only.
- Expandability:
All plumbing manifolds are provided with multiple plumbing stubs for
future use. All electrical systems are designed for additional
capacity for future expansion or upgrade of connected appliances.
- Bus Bar
Systems: Individual circuit breakers mounted
on interchangeable plates for ease of service and relocation. Spare
connection points provided for cooking equipment relocation or
expansion.
- Wireway:
Electrical distribution panel located in the riser is equipped with
branch circuit breakers and sized for expansion.
- Serviceability
and Accessibility: Lift out doors provide easy
access to risers without moving cooking equipment, in most cases.
Removable panels provided along the length of the raceway allow access
to either plumbing or electrical compartments.
- Electric
Outlets and Cord Sets: All outlets are
provided with moisture resistant covers and have been sized per NEMA
standards. Each is supplied with a matching cord and plug set if these
are not already supplied by the equipment manufacturer. Twist-lock
sets are standard with the model EUDI. Straight blade sets are
standard with the model EUDW.
- Main
Disconnect: One point disconnect through a
main circuit breaker equipped with a 120 VAC rated shunt trip provided
in the riser.
- Gas
Solenoid Valve: Electrical or Mechanical.
Electrical valves provided with a manual reset button.
- Shunt
Trip: Provided with each main breaker.
- Appliance
Protection: Each electrical outlet connection
is protected with an individual circuit breaker.
- Dual
Convenience Outlets: Located at each riser
with integral ground fault protection.
- Fire/Fuel
Shutoff: In compliance with NFPA 96, terminal
connection points provided for field wiring to the fire protection
system to shut off fuel sources and power in the event of a fire.
- Customized CAD
Drawings Provided
OPTIONAL
EQUIPMENT:
- Remote Status Indicator Panel:
Lighted panel indicates status of breakers in wireway system.
- Electric Outlets & Cord
Sets: Water tight pin and sleeve outlets and cords.
- Light & Fan Switches
located in riser.
- Hood Control Panel built into
riser.
- Ground Fault Protection
- Prison Package
- Bumper Strips
- Emergency Kill Switch: Single
point shutdown of electrical power and electrical gas valves.
- Swivel Connectors for gas
equipment.
- Plumbing Fixtures: Pre-plumbed
and installed faucets, mixing valves, hose reels.
- Cable Restraints: Available
for mobile equipment.
- Hinged Doors for internal
access to risers.
- Temperature/Pressure Gauges
for hot/cold water main.
SPECIFICATIONS
DESCRIPTION:
Utility Distribution System
shall be the EMPIRE
model EUDI (or EUDW). Overall size shall be as shown on drawings. Systems
shall have two vertical risers, one on each end, with one dedicated to
electrical and the other to plumbing. The horizontal distribution raceway
between the risers shall be separated into electrical and plumbing
compartments and each shall be completely enclosed and water tight with
removable access panels. The risers and raceway shall be constructed of 16
gauge, type 304 stainless steel, #4 finish. The system shall be completely
pre-wired and pre-plumbed with one (1) final connection point for all
incoming services. A circuit protected dual convenience outlet shall be
provided on each riser. Service connections shall be located behind easy
lift out access panels.
ELECTRICAL:
- Bus Bar Systems: The
electrical raceway shall be a four (4) conductor copper bus bar system
having balanced load and phases and shall be completely isolated from
the plumbing supply manifolds. Point of use circuit breakers shall be
mounted on connection plates which are located on the peaked top of
the raceway and protected by a water proof stainless steel hinged
cover. The breakers shall be easily accessible to the operator. The
connection plates shall be easily interchangeable with spare blank
plates which shall be provided for future expansion or changes. A main
circuit breaker with a built-in 120 VAC rated shunt trip shall be
furnished in the electrical riser and require a single point incoming
connection. Terminal block connections shall be provided for field
interconnection between the shunt trip and the fire protection system
for power shut-off in the event of a fire.
- Wireway Systems: The
electrical system shall consist of a main circuit breaker which feeds
power to a distribution panel located in the electrical riser
containing individual branch breakers. Each appliance is fed from the
individual breakers which are wired to each receptacle located along
the raceway and shall be completely isolated from the plumbing supply
manifolds. The main circuit breaker shall be equipped with a built-in
120 VAC rated shunt trip and shall be located in the electrical riser
requiring a single point incoming connection. Terminal block
connections shall be provided for field interconnection between the
shunt trip and the fire protection system for power shut-off in the
event of a fire. All outlets shall be equipped with grounding type
receptacles having specific NEMA polarized configurations and located
on the under side (Model EUDI) or front side (Model EUDW) of the
raceway at each equipment location. Outlets are matched to the cord
and plug sets supplied with equipment. On the Model EUDI, twist lock
cord and plug sets are provided for equipment supplied without cords.
On the Model EUDW, straight blade cord and plug sets are provided for
equipment supplied without cords.
Main Circuit Breaker:15 to 600
Ampere, 1 or 3 phase
- 120, 208, or 480 VAC System
- Branch Circuit Breaker: 15 to
100 Ampere, 1 or 3 phase
- 120, 208, or 480 VAC System
PLUMBING:
The plumbing compartment shall be
completely isolated from the electrical with all piping labeled. Hot and
cold water and steam supply and return manifolds shall be insulated. All
incoming service connections shall be provided with 1/4 shut-off valve.
Each branch connection shall be provided with 1/4 shut-off valve, color
coded, and located at each equipment location. Color coded quick
disconnect hoses are provided for connection to equipment. Hot and cold
water piping, including branch connections, shall be type "L"
copper tubing. All fittings will be copper sweat soldered (95-5 type). Gas
and steam piping, including branch connections, shall be threaded black
iron. There shall be a drip tee on the incoming gas end. The gas manifold
shall be furnished with either an electrical or mechanical gas valve which
shall be field interlocked with the fire protection system to shut off
fuel sources in the event of a fire. Electrical gas valves shall be
furnished with a manual gas reset button located in the EUDS riser.
Gas:
- Manifold (single or looped):
3/4" to 3" IPS
- 1/4 turn manual shut-off valve
on manifold
- Quick disconnect hoses:
1/4" to 1-1/4", up to 6' long
- Quick disconnect fittings:
1/4" to 1-1/4" with 1/4 shut-off valves
Hot
and Cold Water:
Compressed
Air:
- Manifold: 1/2" to
3/4" IPS
- 1/4 turn manual shut-off valve
on manifold
- Quick disconnect hoses:
1/4" to 1/2", up to 6' long
- Quick disconnect fittings:
1/4" to 1/2" with 1/4 shut-off valves
EMPIRE
We're One
Manufacturer You Can Count On For
Quality Products
- Stainless Steel Canopy, Low
Proximity and Water Wash Ventilation Hoods
-- UL LISTED, UL LISTED to Canadian safety standards, NSF LISTED,
built
in accordance with NFPA 96 and recognized by ICBO, BOCA and SBCCI.
- UL Listed Utility Cabinets,
integrally designed with hood and containing:
UL Listed Pre-Piped Fire Suppression System, UL Listed, Pre-wired
Electrical Controls Package
- Roof Top Packages, combining
UL Listed Exhaust and make-up air fans
on a common curb with only one roof opening required. Separate UL
Listed exhaust and make-up air fans also available.
- UL Listed Direct-Fired Heated
Make-up Air Units
- UL Listed Utility Distribution
Systems
Superior Service
- State of the art manufacturing
- Localized sales and
engineering offices nationwide, providing AutoCad
submittal drawings and detailed engineering data.
- Expedient Lead Times
EMPIRE .
reserves the right to modify the design, materials, and/or specifications
as a result of code requirements or product enhancements resulting from
the Company's ongoing research and development.
|