DIMENSIONAL DATA
ECDU SERIES UPBLAST EXHAUST FANS
Direct Driven

FAN DIMENSIONAL
DATA
|
MODEL
|
A
|
B
|
C
|
D
|
E
|
SPEED CONTROLLER
|
R (DIA)
|
FAN WEIGHT
|
|
ECDU110
|
13-1/2
|
15-1/2
|
20-1/4
|
12-14
|
14-1/8
|
3A
|
19-1/2
|
30
|
|
ECDU135
|
19
|
20-1/4
|
25-3/4
|
16-1/2
|
16-1/2
|
6A
|
10-1/2
|
50
|
CURB DIMENSIONAL DATA
| MODEL |
F |
G |
| ECDU110 |
12-1/4 |
28* |
| ECDU135 |
17-3/4 |
24 |
*ECDU110
CURB MAY BE 12" HIGH FOR NON-GREASE APPLICATIONS
FEATURES
- ROOF MOUNTED FANS
- RESTAURANT MODEL
- UL 762 LISTED
- WEATHERPROOF DISCONNECT
- THERMAL OVERLOAD PROTECTION
- DIRECT DRIVE
- SPEED CONTROL MOUNTED AT FACTOR
- GREASE EXHAUST TESTING
Normal Temperature Test: Exhaust fan must operate continuously while
exhausting air at 300°F (148°C) until all fan parts have reached
thermal equilibrium, and without any deteriorating effects to the
fan which would cause unsafe operation.
Abnormal Flare-Up Test: Exhaust fan must operate continuously while
exhausting burning grease vapors at 600°F (315°C) for a period of
15 minutes without the fan becoming damaged to any extent that could
cause an unsafe condition.
- OPTIONAL GREASE CUP AVAILABLE
- OPTIONAL INSULATED CURB

The exhausters shown herein are UL 762 Listed
PERFORMANCE DATA
| FAN MODEL
# |
RPM |
HP |
LICENSED
CFM, and SONES and VS. STATIC PRESSURE |
| 0.000 |
0.125 |
0.250 |
|
| CFM |
Sones |
CFM |
Sones |
CFM |
Sones |
| ECDU110 |
1550 |
1/10 |
1017 |
10.1 |
951 |
10.2 |
885 |
10.6 |
| ECDU110 |
1300 |
1/10 |
853 |
8.1 |
774 |
8.3 |
693 |
7.6 |
| ECDU110 |
1050 |
1/10 |
689 |
6.0 |
591 |
6.2 |
468 |
5.5 |
| ECDU110 |
860 |
1/10 |
564 |
4.5 |
441 |
4.2 |
243 |
4.2 |
| ECDU135 |
1695 |
1/2 |
2736 |
15.7 |
2654 |
16.1 |
2572 |
15.3 |
| ECDU135 |
1550 |
1/2 |
2502 |
13.9 |
2412 |
14.3 |
2323 |
13.6 |
| ECDU135 |
1300 |
1/2 |
2098 |
11.2 |
1991 |
10.6 |
1886 |
10.9 |
| ECDU135 |
1050 |
1/2 |
1695 |
8.3 |
1563 |
8.1 |
1431 |
7.6 |
| ECDU135 |
860 |
1/2 |
1388 |
6.4 |
1228 |
6.2 |
1053 |
5.5 |
| |
| FAN MODEL
# |
RPM |
HP |
LICENSED
CFM, and SONES and VS. STATIC PRESSURE |
| 0.375 |
0.500 |
0.625 |
|
| CFM |
Sones |
CFM |
Sones |
CFM |
Sones |
| ECDU110 |
1550 |
1/10 |
816 |
9.6 |
731 |
9.5 |
617 |
9.5 |
| ECDU110 |
1300 |
1/10 |
588 |
7.5 |
454 |
7.5 |
270 |
7.5 |
| ECDU110 |
1050 |
1/10 |
292 |
5.5 |
| ECDU110 |
860 |
1/10 |
| ECDU135 |
1695 |
1/2 |
2491 |
15.6 |
2410 |
15.6 |
2328 |
14.3 |
| ECDU135 |
1550 |
1/2 |
2234 |
13.8 |
2145 |
13.1 |
2053 |
12.7 |
| ECDU135 |
1300 |
1/2 |
1779 |
10.3 |
1665 |
10.0 |
1522 |
9.6 |
| ECDU135 |
1050 |
1/2 |
1283 |
7.2 |
1070 |
6.8 |
| ECDU135 |
860 |
1/2 |
797 |
5.5 |
| |
| FAN MODEL
# |
RPM |
HP |
LICENSED
CFM, and SONES and VS. STATIC PRESSURE |
| 0.750 |
1.000 |
1.250 |
MAX
BHP |
| CFM |
Sones |
CFM |
Sones |
CFM |
Sones |
| ECDU110 |
1550 |
1/10 |
506 |
9.5 |
|
|
|
|
0.098 |
| ECDU110 |
1300 |
1/10 |
|
|
|
|
|
|
0.057 |
| ECDU110 |
1050 |
1/10 |
|
|
|
|
|
|
0.03 |
| ECDU110 |
860 |
1/10 |
|
|
|
|
|
|
0.016 |
| ECDU135 |
1695 |
1/2 |
2243 |
14.3 |
2052 |
13.8 |
1782 |
13.1 |
0.54 |
| ECDU135 |
1550 |
1/2 |
1953 |
12.3 |
1683 |
11.7 |
1401 |
11.7 |
0.413 |
| ECDU135 |
1300 |
1/2 |
1347 |
9.1 |
|
|
|
|
0.242 |
| ECDU135 |
1050 |
1/2 |
|
|
|
|
|
|
0.128 |
| ECDU135 |
860 |
1/2 |
|
|
|
|
|
|
0.071 |
EMPIRE reserves the right to modify the design,
materials and/or specification as a result of code requirements or
product enhancements resulting from the Company's ongoing research and
development.
|